Manifold air pressure:Rescale project

From S4wiki
Revision as of 17:44, 7 February 2019 by Nyet (talk | contribs) (→‎551G dump)
Jump to navigation Jump to search

Variables

From http://nefariousmotorsports.com/forum/index.php?topic=3027

pvdk_w
pus_w
fvpdkdsl_w
fho_w
frhodkr_w
SDLDSUA axis calculation

Maps

Rescale ps

[%BBBO]
MSNPCV		- Divide axis by 2

[%BGMSZS]
KVLAD		- Multiply by 2
PSSOLPGRD	- Divide by 2
PSSOLNGRD	- Divide by 2
PSSOLPF		- Divide by 2

[%BGSRM]
KISRM		- Divide by 2
KFPRG		- Divide by 2
KFURL		- Multiply by 2

[%DLDUV]*
DLDUVES		- Divide by 2

[%DLDR]
KFDLULS		- Divide both axis and table by 2

[%GGDSAS]
DPDSVLU		- Divide by 2
DSLGRAD		- Divide by 2
DSLOFS		- Divide by 2
DSUGRAD		- Divide by 2 (DSUOFS was zero, otherwise divide by 2)
FHOE		- Divide by 2
PUE		- Divide by 2
PUMN		- Divide by 2
PUMX		- Divide by 2
PVDKMN		- Divide by 2

[%GGLSU]
PADMSA		- Divide curve by 2
FLAMPA		- Divide axis by 2
PUELSU		- Divide by 2

[%GGPBKV]
PBKVVSTG	- Divide both axis and curve by 2
PUEBKV		- Divide by 2

[%LDRPID]
KFLDIMX		- Divide axis by 2
KFLDRQ0		- Divide axis by 2
KFLDRQ1		- Divide axis by 2
KFLDRQ2		- Divide axis by 2
KFLDIOPU	- Divide axis by 2
LDEIAO		- Divide by 2
LDEIAP		- Divide by 2
LDEIAPS		- Divide by 2
LDEIAU		- Divide by 2
NLDIAPU		- Divide axis by 2


[%LDUVST]*
KFSDLDSUA	- Divide both axis and table by 2
HSLDSUA		- Divide by 2
LDUVRS		- Divide by 2

[%RKTI]
FRLFSDP		- Divide axis by 2

Some questionable items

Missing from above, updated later

[%LDRPID]
LDRQ0DY         - Multiply by 2
LDRQ1DY         - Multiply by 2
LDRQ0S		- Multiply by 2
LDRQ1ST		- Multiply by 2
UMDYLDR		- Divide by 2

[%DLDR]
DLUL		- Divide by 2
EDLDRP          - Divide by 2

FHOKH and ZDSU

[%BBKHZ]
FHOKH          - Divide by two or set to 0

[%GGDSU]
ZDSU           - Sqrt and multiply by 2

Sqrt and multiply by 2 does different things depending on if ZDSU is >4 or <4

LDEIAP

0xFE/2 is 0xFF (-1 -> -2)

VCDS hack

M box ONLY!

0x6A338:                      change 7D                      to FA
0x695B0, 0x69416 and 0x6B646: change 7C 84 F1 C8             to EA 00 6E A3
0x69402:                      change F3 FC 43 8B EA 00 BE E6 to F2 F4 84 A2 EA 00 6E A3

551G dump

ID Address Name Size Organization Description Units X Units Y Units Scale X Scale Y Scale Value min Value max Value min*1 Value max*1
KFLDIOPU 0x1970b Korrektur der TV-Werte durch Höheneinfluß 8x8 8 Bit - % hPa Upm 0.64 5.0 40.0 0.0 10.88 0x0 0x11
LDEIAO 0x1978b Obere Regelabweichungsschwelle für Negativ-Verstellung 1x1 8 Bit - hPa - - 10.0 1.0 1.0 20.0 20.0 0x2 0x2
LDEIAP 0x1978c Regelabweichungsschwelle für Positiv Adaption I-Regler 1x1 8 Bit - hPa - - 10.0 1.0 1.0 -20.0 -20.0 0xfe 0xfe
LDEIAPS 0x1978d Regelabweichungsschwelle für schnelle Positiv-Nachführung 1x1 8 Bit - hPa - - 10.0 1.0 1.0 120.0 120.0 0xc 0xc
LDEIAU 0x1978e Untere Regelabweichungsschwelle für Negativ-Verstellung 1x1 8 Bit - hPa - - 10.0 1.0 1.0 -100.0 -100.0 0xf6 0xf6
NLDIAPU 0x1979c Drehzahlschwelle für Adaption I-Begrenzung 2x1 8 Bit - Upm hPa - 40.0 5.0 1.0 2160.0 2600.0 0x36 0x41
UMDYLDR 0x197ab Umschaltschwelle Dynamik LDR 1x1 8 Bit - hPa - - 10.0 1.0 1.0 100.0 100.0 0xa 0xa
ELDOB 0x197ac Regelabweichungsschwelle für Start Zeitzähler LDR-Overboost activ 1x1 8 Bit - hPa - - 10.0 1.0 1.0 50.0 50.0 0x5 0x5
LDPBN 0x19860 LDR p-Begrenzung bei zu hoher Motortemperatur 8x1 8 Bit - hPa Upm - 10.0 40.0 1.0 1350.0 1550.0 0x87 0x9b
KFTVLDRE 0x198d0 Kennfeld tastverhältnisersatzwert für LDR 4x8 8 Bit - % hPa Upm 0.390625 10.0 40.0 10.15625 10.15625 0x1a 0x1a
DLUL 0x198f3 Delta-Last für Überladeschutz-Reset 1x1 8 Bit - hPa - - 10.0 1.0 1.0 20.0 20.0 0x2 0x2
EDLDRP 0x198f4 Schwelle Regelabweichung für Diagnose LDR-Regelabweichung positiv 1x1 8 Bit - hPa - - 10.0 1.0 1.0 100.0 100.0 0xa 0xa
KFDLULS 0x19907 Delta Druck für Überladeschutzdiagnose 8x8 8 Bit - hPa hPa Upm 5.0 10.0 40.0 250.0 1000.0 0x32 0xc8
NDLDRAPU 0x1999c Drehzahlschwelle für LDRA Fehlerpfad und Heilung LDO Fehlerpfad 2x1 8 Bit - Upm hPa - 40.0 5.0 1.0 2520.0 3000.0 0x3f 0x4b
PUDWG 0x199a7 pu- Schwelle für Diagnose Waste- Gate 1x1 8 Bit - hPa - - 5.0 1.0 1.0 1270.0 1270.0 0xfe 0xfe
DPBKVUS 0x1a4e6 gewünschte Druckdifferenz zwischen Bremskraftverstärker und Umgebungsdruck 1x1 8 Bit - hPa - - 5.0 1.0 1.0 0.0 0.0 0x0 0x0
KFPRG 0x1bd30 interner Abgaspartialdruck abhängig von NW-Verstellung bei sumode=0 10x6 16 Bit (LoHi) - hPa U/min °KW 0.0390625 0.25 0.001953125 0.0 320.0 0x0 0x2000
KFURL 0x1bdcc Umrechnungsfaktor von ps->rl abhängig von NW-Verstellung bei sumode=0 10x6 16 Bit (LoHi) - %/hPa U/min °KW 4.57763671875E-6 0.25 0.001953125 0.0 0.123504638671875 0x0 0x6964
DPDSVLU 0x1be46 Delta Druckwert für Signalvergleich Ladedruck mit Umgebungsdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 200.0 200.0 0x1400 0x1400
DPUPVDK 0x1be5a Differenzdruck pu-pvdk 8x1 16 Bit (LoHi) - hPa kg/h - 0.0390625 0.1 1.0 0.0 0.0 0x0 0x0
DSUGRAD 0x1be6a Gradient für Drucksensor Umgebung 1x1 16 Bit (LoHi) - hPa/V - - 0.015625 1.0 1.0 253.453125 253.453125 0x3f5d 0x3f5d
DSUOFS 0x1be6c Offset Drucksensor Umgebung 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
PUE 0x1be6e Ersatzwert für Umgebungsdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 700.0 700.0 0x4600 0x4600
PUMN 0x1be70 Umgebungsdruckbegrenzung minimal 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 350.0 350.0 0x2300 0x2300
PUMX 0x1be72 Umgebungsdruckbegrenzung maximal 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1250.0 1250.0 0x7d00 0x7d00
PUSPSMX 0x1be74 max. Abweichung von Umgebungsdruck und Saugrohrdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 300.0 300.0 0x1e00 0x1e00
PVDKMN 0x1be76 pvdk min. Schwelle für Fehlererkennung Ladedrucksensor 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 400.0 400.0 0x2800 0x2800
PVDKMX 0x1be82 Ladedruckgrenze für Diagnose max. Fehler 4x1 16 Bit (LoHi) - hPa U/min - 0.0390625 0.25 1.0 1300.0 2559.9609375 0x8200 0xffff
PVDKPSMX 0x1be8a max. Abweichung von Saugrohrdruck und Druck vor Drosselklappe 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 210.0 210.0 0x1500 0x1500
KLDPDK 0x1bfda Druckabfall über Drosselklappe 16x1 16 Bit (LoHi) - hPa kg/h - 0.0390625 0.1 1.0 0.0 0.0 0x0 0x0
FRLFSDP 0x1c2a8 Einspritzkorrektur bei RLFS 11x1 16 Bit (LoHi) - - hPa - 3.0517578125E-5 0.078125 1.0 1.0 1.0 0x8000 0x8000
PSAPES 0x1c2c0 Saugrohrdruck für Applikation Einspritzung 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1013.0078125 1013.0078125 0x654d 0x654d
KFLDIMX 0x1d65e Kennfeld LDR I-Reglerbegrenzung 8x16 16 Bit (LoHi) - % hPa U/min 0.0050 0.0390625 0.25 0.0 95.0 0x0 0x4a38
KFLDRQ2 0x1d8f0 Kennfeld LDR-Reglerparameter Q2 4x8 16 Bit (LoHi) - %/100hPa hPa Upm 0.05 10.0 40.0 0.0 25.0 0x0 0x1f4
LDRQ0DY 0x1d95a LDR-Reglerparameter Q0 16x1 16 Bit (LoHi) - %/100hPa Upm - 0.05 40.0 1.0 5.0 30.0 0x64 0x258
LDRQ0S 0x1d97a Reglerparameter Q0 LDR-PID Regler im Stationärbetrieb 1x1 16 Bit (LoHi) - %/100hPa - - 0.05 1.0 1.0 2.0 2.0 0x28 0x28
LDRQ1DY 0x1d97c Reglerparameter Q1 PID-Regler im Dynamikbetrieb (Integrationsbeiwert) 16x1 16 Bit (LoHi) - %/100hPa Upm - 0.05 40.0 1.0 20.0 20.0 0x190 0x190
LDRQ1ST 0x1d99c Reglerparameter Q1 PID-Regler im Stationärbetrieb (Integrationsbeiwert) 16x1 16 Bit (LoHi) - %/100hPa Upm - 0.05 40.0 1.0 0.30000000000000004 0.5 0x6 0xa
DPVRDKMN 0x1ddc4 Relativer Delta- Druck vor DK für Diagnose Waste- Gate 4x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 7.8125 7.8125 0xc8 0xc8
FQTEPT 0x1eb99 Kennlinie Tankunterdruckbegrenzung (pte) 6x1 8 Bit - - hPa - 0.125 0.25 1.0 0.0 0.0 0x0 0x0
KFFLTA 0x1ec54 Schwelle zur Erkennung Feinleck 4x4 8 Bit - s hPa Grad C 0.05 0.0390625 0.75 2.4000000000000004 2.95 0x30 0x3b
KFGLTA 0x1ec72 Schwelle zur Erkennung Grobleck 4x4 8 Bit - s hPa Grad C 0.05 0.0390625 0.75 0.9500000000000001 1.1500000000000001 0x13 0x17
KFXFTA 0x1ec90 Schwelle zur Erkennung Feinstleck (>= 0.5 mm) 4x4 8 Bit - s hPa Grad C 0.05 0.0390625 0.75 5.9 7.0 0x76 0x8c
PUKORRV 0x1ecbc Umgebungsdruckkorrektur abhängig von Fahrzeuggeschwindigkeit 8x1 16 Bit (LoHi) - hPa km/h - 0.0390625 0.0078125 1.0 0.0 0.0 0x0 0x0
DSBOFS 0x1f37e Offset Drucksensor Bremskraftverstärker 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 110.0 110.0 0xb00 0xb00
PBKVVSTG[PV] 0x1f3a2 Unterdruckverstärkung durch Saugstrahleffekt 6x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 0.0 170.0 0x0 0x1100
PUEBKV 0x1f3ae Ersatzwert für Umgebungsdruck für BKV 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 600.0 600.0 0x3c00 0x3c00
DPBKVSPS 0x1f3b4 Delta Druck zw. Sollbremskraftverstärkerdruck und Saugrohrdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 70.0 70.0 0x700 0x700
DPBKVUKKPU 0x1f3c0 min. zuläs. Druckdiff. zw. pbkv und pu für Kompressorabschaltung 4x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 0.0 0.0 0x0 0x0
DPBKVUKNW 0x1f3d2 min. zuläs. Druckdiff. zw. pbkv und pu für NW-Umschaltung auf min. Überschneidun 4x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 220.0 300.0 0x1600 0x1e00
DPBKVUKP 0x1f3e4 min. zuläs. Druckdif. zwischen BKV-Druck und pu für Pumpenansteuerung 4x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 240.0 400.0 0x1800 0x2800
DPBKVUKPU 0x1f3f6 min. zuläs. Druckdif. zw. BKV-Druck und pu ohne Betät. der Bremse abh. von pu 4x1 16 Bit (LoHi) - hPa hPa - 0.0390625 0.0390625 1.0 220.0 300.0 0x1600 0x1e00
OPBKVUKKB 0x1f42a Offset zu DPBKVUKKPU bei betätigter Bremse 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
OPBKVUKNWB 0x1f42c Offset zu DPBKVUKNW bei betätigter Bremse 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
OPBKVUKPB 0x1f42e Offset zu DPBKVUKP bei betätigter Bremse 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
OPBKVUKPUB 0x1f430 Offset zu DPBKVUKPU bei betätigter Bremse 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
PBKVKREHY 0x1f432 Hysterese zur kritischen Obergrenze für Druck im BKV für Ersatzmaßnahmen 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 50.0 50.0 0x500 0x500
PBKVKRHY 0x1f434 Hysterese zur kritischen Obergrenze für Druck im Bremskraftverstärker 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 170.0 170.0 0x1100 0x1100
DPBKVP 0x1f438 Druckdelta, das in der Zeit TDDBKVP evakuiert werden kann 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 25.0 25.0 0x280 0x280
DPBKVPMN 0x1f43a Toleranz von pubkv_w*FBKVP (min. Pump-Druck) und Toleranz Drucksensor im BKV 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 60.0 60.0 0x600 0x600
DPBKVLE 0x1f440 zulässiger Druckanstieg bei Leckage 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1278.984375 1278.984375 0x7fe6 0x7fe6
DPSBKV 0x1f442 Delta Druck für Plausibilität von Bremskraftverstärkerdruck mit Saugrohrdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 250.0 250.0 0x1900 0x1900
DPSPBKVNPH 0x1f444 min. Druckdifferenz zw. ps und pbkv für Heilung npl-Fehler(Leckage) 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 -1280.0 -1280.0 0x8000 0x8000
DPUBKV 0x1f446 Delta Druck für Plaus. von Bremskraftverstärkerdruck mit Umgebungsdruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 2550.0 2550.0 0xff00 0xff00
PBKVMN 0x1f448 min. möglicher Druck im Bremskraftverstärker 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 100.0 100.0 0xa00 0xa00
PBKVMX 0x1f44a max. möglicher Druck im Bremskraftverstärker 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1190.0 1190.0 0x7700 0x7700
SLD04LDUB 0x10070 Stützstellenverteilung für Ladedruckregelung 4x1 8 Bit - hPa ? - 10.0 1.0 1.0 0.0 700.0 0x0 0x46
SPU08LDUB 0x100d3 Stützstellenverteilung für Ladedruckregelung 8x1 8 Bit - hPa ? - 5.0 1.0 1.0 600.0 1010.0 0x78 0xca
DPUPS 0x10da1 Druckdifferenz für Umschaltung Referenzdruck vor Drosselklappe 1x1 8 Bit - hPa - - 10.0 1.0 1.0 300.0 300.0 0x1e 0x1e
HSLDSUA 0x11121 Hysterese für stationäre Schubumluftventilansteuerung 1x1 8 Bit - hPa - - 10.0 1.0 1.0 10.0 10.0 0x1 0x1
LDUVRS 0x11123 LDR Umluftventilsteuerung Reset vom Sollwert 1x1 8 Bit - hPa - - 10.0 1.0 1.0 0.0 0.0 0x0 0x0
SDLDSUA 0x11125 Schwelle für dynamische Schubumluftventilsteuerung aktiv 16x1 8 Bit - hPa hPa - 10.0 160.0 1.0 350.0 600.0 0x23 0x3c
KFVPLGU 0x11135 Kennfeld für Grundladedruckverhältnis LDR 8x8 8 Bit - - hPa U/min 0.0078125 0.0390625 0.25 1.0 1.0 0x80 0x80
SPL08LDUW 0x12b3e Stützstellenverteilung für Ladedruckregelung 8x1 16 Bit (LoHi) - hPa ? - 0.0390625 1.0 1.0 250.0 1000.0 0x1900 0x6400
DSLGRAD 0x13e4a Gradient für Drucksensor Ladedruck 1x1 16 Bit (LoHi) - hPa/V - - 0.015625 1.0 1.0 541.0 541.0 0x8740 0x8740
DSLOFS 0x13e4c Offset Drucksensor Ladedruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 -16.40625 -16.40625 0xfe5c 0xfe5c
PLSOLAP 0x13fb4 Applikationswert für Soll-Ladedruck 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 0.0 0.0 0x0 0x0
SPS08LDUW 0x15762 Stützstellenverteilung für Ladedruckregelung 8x1 16 Bit (LoHi) - hPa ? - 0.0390625 1.0 1.0 1.171875 9.375 0x1e 0xf0
DPLSDWG 0x1578b Max. Delta plsol für Diagnose Waste- Gate 8x1 16 Bit (LoHi) - hPa Upm - 0.0390625 40.0 1.0 0.0 2320.0 0x0 0xe800
DPVDKDWG 0x157a5 Min. Delta Druck vor DK für Diagnose Waste- Gate 8x1 16 Bit (LoHi) - hPa Upm - 0.0390625 40.0 1.0 0.0 2320.0 0x0 0xe800
DSTGRAD 0x168e0 Gradient für Umrechnung Spannung -> Druck bei Tankdrucksensor 1x1 16 Bit (LoHi) - hPa/V - - 0.001953125 1.0 1.0 0.0 0.0 0x0 0x0
KLTDS 0x168f2 Konvertierungskennlinie für Tankdrucksensor DS-T2 6x1 16 Bit (LoHi) - hPa hPa - 9.77E-4 0.00244140625 1.0 -32.014336 32.013359 0x8000 0x7fff
DPUBABMX 0x1690c Maximale Schwelle Delta Umgebungsdruck für Bergaberkennung 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 4.0234375 4.0234375 0x67 0x67
DPUFFMN 0x1690e Minimale Schwelle für Delta-Umgebungsdruck, Bergauferkennung (0.5 mm - Diagnose) 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 -4.0234375 -4.0234375 0xff99 0xff99
DPUFFMX 0x16910 Maximale Schwelle für Delta-Umgebungsdruck, Bergaberkennung (0.5 mm - Diagnose) 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 4.0234375 4.0234375 0x67 0x67
DPUFVMN 0x16912 Spezifische Druckdifferenz für Saugrohrdrucküberwachung 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 150.0 150.0 0xf00 0xf00
DPUFVSMN 0x16914 Soll-Druckdifferenz für Saugrohrdrucküberwachung 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 -500.0 -500.0 0xce00 0xce00
DIFFMAX 0x16990 max. zulässige Druckänderung während 100ms 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1.9921875 1.9921875 0x33 0x33
PUSMAX 0x16992 maximal plausible Umgebungsdruckschwelle 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 1150.0 1150.0 0x7300 0x7300
PUSMIN 0x16994 minimal plausible Umgebungsdruckschwelle 1x1 16 Bit (LoHi) - hPa - - 0.0390625 1.0 1.0 450.0 450.0 0x2d00 0x2d00
DPVLMS 0x169a4 Druckabfall am Luftfilter zur Berechnung Massestrom Tankentlüftung hinter Lader 6x1 16 Bit (LoHi) - hPa kg/h - 0.0390625 0.1 1.0 0.0 40.0 0x0 0x400
DPSLV 0x18348 minimale Druckdifferenz Sekundärluftventi 1x1 8 Bit - hPa - - 5.0 1.0 1.0 0.0 0.0 0x0 0x0

Legend:

  • Bold: In original map pack
  • Bold and italic: Added later
  • Italic: Missing