VAG-COM blocks 034 and whatever else only display an internally calculated O2 sensor temperature, which is what most people think are real EGTs. That value may or may not have anything to do with the real EGTs or temperature at the primary O2 sensors; in fact, those temperature values are stored in 2 maps where the inputs are load and RPM.

Block 112 is the only block where a real EGT value is displayed, and only when the actual EGTs exceed 945°C. This is only due to the design of the sensors and their electronic modules, which makes that they can only "read" 945-1035°C and that's all. So basically if all you see is 945 all the time, it means your actual EGTs never exceed 945.

If you see block 034 EGTs hitting 750 or 800 or 850, those values have never been, are not and will never be actual EGTs. The only real EGTs are in block 112. If you want to know what they are when they're below 945, then you have to use RS6 sensors with adequate programming, so you get a range of -40 to 1100°C and then you will know what your real EGTs are.

EGT enrich

There are two types of EGT enrich in ME7

  • BTS (open loop) - when modeled EGT (block 034) reaches TABGBTS (500°C for the S4, 750°C for the RS4), the requested AFR tracks lambts if it is richer than lamfa.
  • ATR (closed loop) - when measured EGT (block 112) reaches TABGSS (980°C), ATR will add fuel via dlatr, which is generated by the ATR PID.

Audi documentation

Exhaust gas temperature control

For turbocharged engines, the maximum permissible exhaust gas temperature is a key design criterion.

To protect the exhaust gas turbocharger and the exhaust manifold, the exhaust gas temperature should not exceed 1000°C for a lengthy period of time.

Since many of the components which influence the exhaust gas temperature have tolerances, thermodynamic adaptation previously took place at 950°C for safety's sake.

This was achieved by enriching the air/fuel mixture.

The exhaust gas temperature is recorded in a cylinder-bank-specific manner by the two exhaust gas temperature senders G235 and G236.

The Motronic controls the exhaust gas temperature to 980°C by enriching the air/fuel mixture.

It is therefore possible to largely dispense with the prophylactic enrichment process that has been standard practice until now.

The mixture is only enriched

  • when necessary and
  • to the extent necessary.

This means that engine operation with lambda = 1 is possible up to high load and engine speed ranges.


To facilitate exhaust gas temperature control, the exhaust gas temperature must be recorded to a high degree of accuracy.

An accuracy of ±5°C is achieved in the measurement range from 950°C to 1025°C. The exhaust gas temperature sender is located inside the exhaust manifold upstream of the exhaust gas turbocharger.

It comprises a measuring sensor and evaluation electronics.

Sensor design

Physical construction

The measuring sensor consists of a thermocouple of unknown type. This thermocouple probe is attached to a control unit by means of a heat-resistant insulated cable with stainless steel over-braid shield.

Electronics design

The evaluation electronics within the control unit convert the microvolt level thermocouple signal into a pulse-width-modulated signal (PWM signal) that can be interpreted by the ECU. The signal output consists of a square wave with a fixed frequency of 10Hz; meaning the ECU can be provided with 10 updated temperatures per second. The pulse width duty cycle is expressed as a percentage of signal high-time to the overall signal period. The sensor output ranges from a minimum pulse width of 5% to a maximum of 95%. The values above and below this range is reserved for the ECU to perform sensor diagnostics.

ECU signal conversion

ECU analog to digital conversion

The ECU interprets the signal generated by sensor package and converts it to a temperature value. The ECU first determines the period of the signal and then compares the signal high time to the period to determine the signal duty cycle. The period of the signal is converted to a temperature value against table TABGTA. The resultant temperature (TATS_W for bank 1 or TATS2_W for bank 2) is delivered in celsius units with possible ranges between 940C to 1035C.

Substitute function and self-diagnosis

The ECU is capable of producing four unique fault codes for various error a sensor fault states. In the event of a sensor fault the ECU will fail-over to the working sensor to provide enrichment. In the event that both sensors have faults the ECU will fail over to an EGT limp mode where emergency enrichment characteristic (engine speed-dependent) is utilized. The error condition must exist for three seconds (TVEATSS) for the sensor to be flagged with an error code and produce one of the following DTCs. The condition will be reset after 3 seconds (TVEATSR) of error free sensor operation.

Exhaust gas temperature sensor (1 or 2) Open/Short to B+:

DTC is produced when the exhaust gas temperature value (TATS_W or TATS2_W) is greater than TATSMX. The stock value of TATSMX is 1034.51C. This correlates to an pulse width duty cycle of greater than 99% based on empirical data.

DTC 17861 indicates this fault for bank 1 (G235) (B_MXATS) while 17865 indicates this fault for bank 2 (G236) (B_MXATS2).

Exhaust gas temperature sensor (1 or 2) Short to Ground:

DTC is produced when the exhaust gas temperature value (TATS_W or TATS2_W) is less than TATSMN. The stock value of TATSMN is 940.49C. This correlates to an pulse width duty cycle of less than 1% based on empirical data.

DTC 17862 indicates this fault for bank 1 (G235) (B_MNATS) while 17866 indicates this fault for bank 2 (G236) (B_MNATS2).

Exhaust gas temperature sensor (1 or 2) Implausible Signal:

DTC is produce at engine idle when the exhaust gas temperature value (TATS_W or TATS2_W) is greater than TATSNP (default value of 950.00C) while the pre-catalytic converter modeled exhaust gas temperature (TABGM-W available to measure in block 034) is less than TDATSO (default value of 500C).

DTC 17863 indicates this fault for bank 1 (G235) (B_NPATS) while 17867 indicates this fault for bank 2 (G236) (B_NPATS2).

Exhaust gas temperature sensor (1 or 2) Signal Error:

DTC is produce when the signal period is outside side of the period tolerance limit defined by DTPATS (default value of 50ms).

It is assumed DTC 17864 indicates this fault for bank 1 (G235) (B_SIATS) while 17868 indicates this fault for bank 2 (G236) (B_SIATS2).